ELECTRIC DUCTED FAN UNIT – KNOWN POWER SYSTEM SETUPS
Please Note:
Wattage and Thrust may vary up to +/- 8% due to battery capacity, C rating, accuracy of ratings/tools and age of the LiPo packs. Use the data found in the tables for your own information only.
Voltage, Current, Wattage and Thrust (kg) have been measured after the System has been running at WOT for 15-35 seconds. Data has been organized by cells in series.
ChangeSun 90mm 12 Blade – CS9012
Safest operation is under 2800 watts. Be certain to balance your fan.
Cell | Battery | Capacity | C | Motor | KV | ESC Make/Model | Timing | Volts | Amps | Watts | Thrust |
---|---|---|---|---|---|---|---|---|---|---|---|
5 | Nanotec | 4400 | 65 | Turnigy L3025 | 1500 | HK 190/200A | 1 deg | 19 | 82 | 1550 | 2.45 |
6 | Zippy | 5800 | 30 | XK3674 | 1400 | Turnigy Plush 100 | low | 21.1 | 82 | 1730 | 2.3 |
8 | Turnigy | 4000 | 30 | Typhoon 700-68 | 1200 | Castle ICE 100 | stock | 26.8 | 70 | 1876 | 3.12 |
10 | Turnigy | 5000 | 30 | Typhoon 700-68 | 900 | Castle HV 110 | stock | 37.1 | 66 | 2450 | 3.35 |
10 | Turnigy nano-tech | 4500 | 35 | Typhoon 700-68 | 1200 | Castle Ice2 HV120 | stock | 34.6 | 95 | 3290 | 4.41 |